Factory setting
Open
The factory setting of the port is "Open".
Closed
The factory setting of the port is "Closed".
Authentication
Specifies whether or not the protocol is authenticated.
Protocol Port number Port status Factory setting of the
port
Authentication
SSH TCP/22 Open (when config‐
ured)
Open Yes
TELNET TCP/23 Open (when config‐
ured)
Open Yes
HTTP TCP/80 Open (when config‐
ured)
Open Yes
HTTPS TCP/443 Open (when config‐
ured)
Open Yes
SNTP
NTP
UDP/123 Open (when config‐
ured)
Closed No
SNMP UDP/161 Open (when config‐
ured)
Open Yes
PROFINET UDP/34964,
UDP/49154,
49155
Open Open No
Syslog UDP/514 Open (when config‐
ured)
Open No
EtherNet/IP TCP/44818,
UDP/
2222,44818
Open (when config‐
ured)
Open No
DHCP UDP/67,68 Open (when config‐
ured)
Closed No
RADIUS UDP/
1812,1813
Open (when config‐
ured)
Closed No
TFTP UDP/69 Open (when config‐
ured)
Closed No
Security recommendations
SCALANCE W760/W720
10 Operating Instructions, 09/2017, C79000-G8976-C322-08

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals