Security recommendations
SCALANCE W774-1 / W734-1
Operating Instructions, 03/2022, C79000-G8976-C325-15
15
If
non-secure protocols and services are required, ensure that the device is operated
in a protected network area.
Check whether use of the following protocols and services is necessary:
Non-authenticated and unencrypted ports
LLDP
Syslog
DHCP options 66/67
TFTP
Telnet
HTTP
SNMP v1/2c
Syslog
SNTP
The following protocols provide secure alternatives:
SNMPv1/v2c SNMPv3
Check whether use of SNMPv1/v2c is necessary. SNMPv1/v2c is classified as
non-secure. Use the option of preventing write access. The product provides you
with suitable setting options.
If SNMP is enabled, change the community names. If no unrestricted access is
necessary, restrict access with SNMP.
Use SNMPv3 in conjunction with passwords.
HTTP HTTPS
Telnet SSH
TFTP SFTP
Syslog Client Syslog Client TLS
Using a firewall, restrict the services and protocols available to the outside to
a
mini
mum.
For the DCP function, enable the "Read Only" mode after commissioning.
List of available services
The following is a list of all available services and their ports through which the device
can be accessed.
The table includes the following columns:
Service
The services that the device supports
Default port status
This is the status of the port in the delivery state (factory setting).

Other manuals for Siemens SCALANCE W774-1 RJ-45

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W774-1 RJ-45 and is the answer not in the manual?

Siemens SCALANCE W774-1 RJ-45 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W774-1 RJ-45
CategoryWireless Access Point
LanguageEnglish

Related product manuals