Description of the SCALANCE W78x
Operating Instructions SCALANCE W78x
41
Standard Cable
C79000-G8976-C184-07
Color Coding of the White /
Orange *
Orange
White /
Green *
Green
Connector color
code (Siemens IE)
White
Blue
Yellow
Orange
Siemens IE FC RJ-
45 socket (reference)
3 6 1 2
* White wire of the particular pair.
Insert the all the data leads at the
same time into the splice element is
far as they will go.
Close the splice element and RJ-45
data module until they lock together.
Insert the data module and the splice
element into the supplied IDC
assembly tool.
Press the data module and the IDC
assembly tool together to establish
the installation piercing connection.