EasyManuals Logo
Home>Siemens>Network Router>SCALANCE X308-2M

Siemens SCALANCE X308-2M User Manual

Siemens SCALANCE X308-2M
314 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #162 background imageLoading...
Page #162 background image
Technical specifications
8.2 X-300 technical specifications
SCALANCE X-300
162 Operating Instructions, 02/2012, A5E01113043-12
Table 8- 16 Full wire speed switching
Number of frames per second
At 100 Mbps At 1000 Mbps
At a frame length of
148810 1488095 64 bytes
84459 844595 128 bytes
45290 452899 256 bytes
23496 234962 512 bytes
11973 119732 1024 bytes
9615 96154 1280 bytes
8127 81274 1518 bytes
Note
The following applies to IE Switches X-300:
The number of IE Switches X-300 connected in a line influences the frame delay time. When
a frame passes through the switch, this is delayed by the Store&Forward function of the
IE Switch X-300 by the following values:
• at 64 bytes frame length: Delay of approx. 10 microseconds (at 100 Mbps)
• at 1500 bytes frame length: Delay of approx. 130 microseconds
(at 100 Mbps)
This means, the more IE Switches X-300 a frame runs through, the higher the frame delay.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X308-2M and is the answer not in the manual?

Siemens SCALANCE X308-2M Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X308-2M
CategoryNetwork Router
LanguageEnglish

Related product manuals