Table 8- 121 Electrical data: Current consumption and power loss I
Product variant Current consumption Effective power loss
MM992-2CUC 70 mA 1.65 W
MM992-2CU 70 mA 1.65 W
MM992-2M12 70 mA 1.65 W
MM991-2 100 mA 2.42 W
MM991-2LD 80 mA 2.04 W
MM991-2 (SC) 100 mA 2.42 W
MM991-2LD (SC) 80 mA 2.04 W
MM991-2LH+ (SC) 80 mA 2.04 W
MM992-2 70 mA 1.76 W
MM992-2LD 80 mA 1.95 W
MM992-2LH 90 mA 2.11 W
MM992-2LH+ 100 mA 2.42 W
MM992-2ELH 110 mA 2.75 W
Table 8- 122 Electrical data: Current consumption and power loss II
MM992-2SFP with Current consumption Effective power loss
SFP991-1 60 mA 1.54 W
SFP991-1LD 60 mA 1.54 W
SFP991-1LH+ 70 mA 1.65 W
SFP992-1 60 mA 1.38 W
SFP992-1LD 70 mA 1.60 W
SFP992-1LH 70 mA 1.71 W
SFP992-LH+ 80 mA 1.93 W
SFP992-1ELH 100 mA 2.31 W
SFP991-1ELH200 100 mA 2.31 W
Note
Fusing and signal contacts with media modules
The MM900 media modules do not have their own fuses and have no signaling contacts.
The fuses and the signaling contacts exist in the SCALANCE device.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X308-2M and is the answer not in the manual?

Siemens SCALANCE X308-2M Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X308-2M
CategoryNetwork Router
LanguageEnglish

Related product manuals