Description of the device 
  3.2 SELECT/SET button 
SCALANCE XR-500 
Operating Instructions, 05/2017, A5E03275845-11 
27 
Using the fault mask, you specify an individual "good status" for the connected ports and the 
power supply. Deviations from this status are displayed as errors/faults. 
To define the fault mask, follow the steps below: 
1.  Change to display mode D. 
Display mode D is active when the "DM1" and "DM2" LEDs are lit green. 
If a different display mode is active, press the "SET/SELECT" button several times briefly, 
until the "DM1" and "DM2" LEDs are lit green. 
2.  Hold down the "SELECT/SET" button for 5 seconds. 
After 2 seconds, the "DM1" and "DM2" LEDs start to flash for 3 seconds. At the same 
time the port LEDs go on one after the other. 
After you have pressed the button for 5 seconds, the current settings are stored as the 
"good status". 
If you release the button before the 5 seconds are up, the previous fault mask is retained. 
Enabling/disabling the redundancy manager 
To enable/disable the redundancy manager, follow the steps below: 
1.  Change to display mode B. 
Display mode B is active when the "DM1" LED is lit green and the and "DM2" LED is off. 
If a different display mode is active, press the "SET/SELECT" button several times briefly, 
until the "DM1" LED is lit green and the "DM2" LED is off. 
2.  Hold down the "SELECT/SET" button for 5 seconds. 
After 2 seconds, the "DM1", "DM2" and "RM" LEDs start to flash for 3 seconds. At the 
same time, the port LEDs light up one after the other. 
If you release the button before the 5 seconds have elapsed, the action is canceled. 
The result of the action depends on the initial situation: 
– 
 
The redundancy manager and media redundancy are disabled. 
 
After enabling the redundancy manager, media redundancy is also enabled. 
– 
 
The redundancy manager and media redundancy are enabled. 
 
After disabling the redundancy manager, media redundancy remains enabled.