Product Type | Industrial Ethernet Switch |
---|---|
Operating Temperature | -40 °C to +70 °C |
Protection Class | IP30 |
Layer | Layer 2 |
Ports | 24 x 10/100/1000Base-T, 4 x 100/1000Base-X |
Power Supply | 24 V DC |
Mounting Type | DIN Rail |
Standards | IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.1Q |
Describes the design, functions, and support for installation, commissioning, and troubleshooting.
Lists other relevant documents and resources for additional information and support.
Details compliance with CE mark and other relevant industry standards.
Specifies requirements for safe operation regarding mechanical stability, flame retardancy, and shock protection.
Provides warnings and guidelines for operating devices in hazardous environments.
Details specific requirements for operation in ATEX-classified hazardous areas.
Explains the fundamental principles of Ethernet switching and its functions.
Describes available network topologies like linear, star/tree, and ring structures.
Explains the structure and meaning of the product type designations for IE Switch X-300.
Details the specifications and types of MM900 media modules available.
Provides information on SFP transceivers, including types and specifications.
Lists compatible devices and network components for IE Switches X-300.
Details the different product groups within the SCALANCE X-300 series.
Provides essential safety and installation guidelines to follow during setup.
Outlines the various methods available for installing the IE Switches X-300.
Details the procedures for installing switches on DIN rails, standard rails, walls, and racks.
Provides a step-by-step procedure for connecting the device to power and network.
Explains how to properly connect the grounding for different installation types.
Details the connection procedures and safety requirements for 24 VDC power supply.
Explains how to assign and label slots for media modules.
Describes the functions and operations of the SET/SELECT button.
Explains the meaning of different LEDs for device status and functions.
Details operating temperature ranges based on media module usage.
Provides detailed technical specifications for the X-300 product line.
Lists connector types and electrical data for various device variants.
Lists the approvals and certificates for the X-300 product group.
Details ATEX approval information for devices used in potentially explosive atmospheres.
Provides information on how to find the EC Declaration of Conformity for the X-300 series.
Lists available accessories and their order numbers for SCALANCE devices.
Shows dimension drawings for small, medium, and large device variants.
Provides dimension drawings specific to the X-300M product group.
Details the connector pinout for TP ports on IE Switch X-300.