Technical specifications
8.6 XR-300M EEC technical specifications
SCALANCE X-300
186 Operating Instructions, 02/2012, A5E01113043-12
8.6.2 Connectors and electrical data
Table 8- 69 Connection for end devices or network components
Max. number 24 ports
Electrical 16 x RJ-45 jacks
10/100/1000 Mbps
Media module slots 4 x modular
(2 ports per slot)
Transmitter output (optical) and receiver input The values correspond to those of the permitted
MM900 media modules and SFP transceivers.
Diagnostics port RJ-11 jack
Table 8- 70 Electrical data: Power supply
Device version
(power supply)
Redundant
power supply
unit
Redundant power
supply possible
Power supply
(min./max. range)
1 x 24 to 48 VDC No Yes 24 to 48 VDC
(19.2 to 57.6 VDC)
2 x 24 to 48 VDC Yes Yes 24 to 48 VDC
(19.2 to 57.6 VDC)
1 x 100 to 240 VAC /
60 to 250 VDC
No No 100 to 240 VAC
(80 to 276 VAC)
60 to 250 VDC
(48 to 300 VDC)
2 x 100 to 240 VAC /
60 to 250 VDC
Yes No 100 to 240 VAC
(80 to 276 VAC)
60 to 250 VDC
(48 to 300 VDC)
Table 8- 71 Electrical data: Current consumption and power loss
Device version
(power supply)
Current consumption Effective power loss
24 to 48 VDC 1.6 to 0.75 A 40 W
100 to 240 VAC /
60 to 250 VDC
0.6 to 0.37 A (AC)
0.7 to 0.17 A (DC)
42 W (AC)
42 W (DC)