Installation
5.2 Installing a switch
SCALANCE X-300
Operating Instructions, 02/2012, A5E01113043-12
115
Table 5- 3 Legend for rack mounting of two IE-Switches X-300EEC fastened together
No. Name
1 Plate for side
2 Spring washer
3 Hexagonal nut
5 Side section (the side panel should be under slight tension)
7 IE Switch X-300EEC
5.2.6 19" rack mounting - XR-300M EEC product group
WARNING
Use of approved components
Use only approved 19" cabinets.
Use only supplied mounting brackets.
There are several ways of fixing the mounting brackets depending on the mounting
position required.
Grounding
WARNING
PE connection with X-300EEC and XR-300EEC
Grounding simply via the housing is inadequate. For safe operation, the protective ground
must be connected to the grounding bolts.
On the SCALANCE X-300EEC, the PE connector is on the bottom of the device. On the
SCALANCE XR-300M EEC, the PE connector is on the rear of the device between the
power connectors.