Technical specifications
8.5 Technical specifications for X-300EEC
SCALANCE X-300
176 Operating Instructions, 02/2012, A5E01113043-12
8.5.1 Construction, installation and environmental conditions
Table 8- 47 Construction
Device version
(power supply)
Dimensions (W x H x D) Weight Degree of
protection
1 24 VDC power supply unit
Without clip:
60 × 125 × 123 mm
With clip:
216 × 203 × 99 mm
1 800 g IP30
2 x 24 VDC power supply
units
Without clip:
60 × 125 × 123 mm
With clip:
216 × 203 × 99 mm
2 030 g IP30
1 x power supply unit
100 to 240 VAC / 60 to 250
VDC
Without clip:
60 × 125 × 123 mm
With clip:
216 × 203 × 99 mm
1 850 g IP30
2 x power supply units
100 to 240 VAC / 60 to 250
VDC
Without clip:
60 × 125 × 123 mm
With clip:
216 × 203 × 99 mm
2 120 g IP30
Table 8- 48 Installation options
Installation options
DIN rail
S7-300 standard rail
1)
Wall
2)
19" rack
3)
1)
Possible only with adapter (must be provided by installers).
2)
Wall mounting possible with suitable wall support.
3)
With mounting support
Table 8- 49 Permitted ambient conditions
Storage/transport
temperature
Operating temperature Max. relative
humidity in
operation at 25 °C
Max. ambient temperature
at operating altitude
-40 °C to +70 °C -40 °C to +70 °C
1)
< 95 % (no
condensation)
Max. 65 °C as of 2 000 m
Max. 60 °C as of 3 000 m
1)
The IE Switch was type tested for 16 h at +85 °C.