Assembling   
4.1 Safety notices for installation 
  SCALANCE XR-500 
38  Operating Instructions, 05/2017, A5E03275845-11 
 
Damage to the device due to inadequate cooling 
If the ventilation slits are fully or partly covered, the temperature inside the housing can rise 
and exceed the maximum permitted temperature causing damage to the device. 
The ventilation slits are located on the side panels of the housing. During installation, select 
a mounting position so that the ventilation slits are always free so that the air can circulate. 
The clearance to the ventilation slits of the housing must be at least 10 cm. 
You will find information about cleaning the air filter in the section "Upkeep and 
maintenance". 
Close unused module slots of modular devices with dummy covers. Open module slots 
impair the air circulation and can damage the device. 
If you mount a SCALANCE XR524-8C or SCALANCE XR526-8C in a rack, leave at least 
one height unit free above and below. 
 
Warming and premature aging of the IE switch due to direct sunlight 
Direct sunlight can heat up the device and can lead to premature aging of the IE switch and 
its cabling. 
Provide suitable shade to protect the IE switch against direct sunlight. 
 
Note 
During installation and operation, keep
 to the installation guidelines and safety notices 
described in this document and in the system manuals "Industrial Ethernet / PROFINET 
Industrial Ethernet" and "Industrial Ethernet / PROFINET passive network components".
 
information on the system manuals in the section "Introduction (Page 5)", in 
 
Safety notices on use in hazardous areas 
General safety notices relating to protection against explosion 
 
Replacing components may impair suitability for Class 1, Division 2 or Zone 2. 
 
 
The device is intended for indoor use only.