Configuring with Web Based Management
4.3 "Information" menu
SCALANCE SC-600 Web Based Management (WBM)
100 Configuration Manual, 10/2021, C79000-G8976-C475-03
Advertisement Interval Errors
Shows how many bad VRRPv3 packets were received whose interval does not match
the value set locally.
IP TTL Errors
Shows how many bad VRRPv3 packets were received whose TTL (Time to live) value
in the IP header is incorrect.
Prio 0 received
Shows how many VRRPv3 packets with priority 0 were received. VRRPv3 packets with
priority 0 are sent when a master router is shut down. These packets allow a fast
handover to the relevant backup router.
Prio 0 sent
Shows how many VRRPv3 packets with priority 0 were sent. Packets with priority 0
are sent when a master router is shut down. These packets allow a fast handover to
the relevant backup router.
Invalid Type
Shows how many bad VRRPv3 packets were received whose value in the "Type" field
of the IP header is invalid.
Address List Errors
Shows how many bad VRRPv3 packets were received whose address list does not
match the locally configured list.
Packet Length Errors
Shows how many bad VRRPv3 packets were received whose length is not correct.

Table of Contents