4.5 "Layer 2" menu
SCALANCE SC-600 Web Based Management (WBM)
248 Configuration Manual, 10/2021, C79000-G8976-C475-03
• Power Loss [dB] Maintenance Required (Warning)
Specify the value at which you are informed of the power loss of the connection by a
message of the severity level "Warning".
If you enter the value "0", the power loss is not monitored.
Default: -50 dB
• Power Loss [dB] Maintenance Demanded (Critical)
Specify the value at which you are informed of the power loss of the connection by a
message of the severity level "Critical".
If you enter the value "0", the power loss is not monitored.
Default: -55 dB
Configuration procedure
Activating fiber monitoring
Follow the steps below to activate the monitoring of a port:
1. Select the appropriate check box in the "Status" column.
2. For your setup, enter practical values value at which you want to be informed of
deterioration of the received power and the power loss of the connection.
3. Click the "Set Values" button.
Deactivating fiber monitoring
Follow the steps below to deactivate the monitoring of a port:
1. Deselect the appropriate check box in the "Status" column.
2. Click the "Set Values" button.
Follow the steps below to deactivate the monitoring of the Rx power or power loss:
1. Enter the value "0" in the appropriate box.
2. Click the "Set Values" button.
4.5.8 Unicast
4.5.8.1 Filtering
Address filtering
This table shows the unicast addresses entered statically by the user during parameter
assignment.
On this page, you also define the static unicast filters.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC646-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC646-2C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC646-2C
CategorySwitch
LanguageEnglish

Related product manuals