Configuring with Web Based Management
4.3 "Information" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
107
SNMP
You can configure setting in "System > SNMP > General".
"-" (SNMP disabled)
Access to device parameters via SNMP is not possible.
SNMPv1/v2c/v3
Access to device parameters is possible with SNMP versions 1, 2c or 3.
SNMPv3
Access to device parameters is possible only with SNMP version 3.
Login Authentication
You configure the setting in "Security > AAA > General".
Local
The authentication must be made locally on the device.
RADIUS
The authentication must be handled via a RADIUS server.
Local and RADIUS
The authentication is possible both with the users that exist on the device (user
name and password) and via a RADIUS server.
The user is first searched for in the local database. If the user does not exist there,
a RADIUS query is sent.
RADIUS and fallback local
The authentication must be handled via a RADIUS server.
A local authentication is performed only when the RADIUS server cannot be
reached in the network.
Password Policy
Shows which password policy is currently being used.
Local and external user accounts
You configure local user accounts and roles in "Security > Users".
When you create a local user account an external user account is generated
automatically.
Local user accounts involve users each with a password for logging in on the device.