EasyManua.ls Logo

Siemens SIMATIC NET SCALANCE SC646-2C

Siemens SIMATIC NET SCALANCE SC646-2C
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring with Web Based Management
4.7 "Security" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
345
The User Specific BFP table has the following columns:
User
The users configured locally on the device. The users that are not locally configured
on the device are summarized under the user name "UnknownUser".
Failed Logins
The number of failed login attempts.
Last Failed [s]
Time in seconds (s) since the last failed login attempt. To display the current value,
click the "Refresh" button.
Blocked [s]
The time in seconds (s) until the blocking will be removed. To display the current
value, click the "Refresh" button.
When a blocked user attempts to log in before the timer expires, the timer restarts.
Delete
Ends blocking for the user and resets the displays in the "Last Failed [s]" and
"Blocked [s]" boxes.
The IP Specific BFP table has the following columns:
IP
The IP address of the device for the login attempt.
Failed Logins
The current number of failed login attempts.
Last Failed [s]
Time in seconds (s) since the last failed login attempt. To display the current value,
click the "Refresh" button.
Blocked [s]
The time in seconds (s) until the blocking will be removed. To display the current
value, click the "Refresh" button.
When a blocked IP address attempts to log in before the timer expires, the timer
restarts.
Delete
Ends blocking for the IP address and resets the displays in the "Last Failed [s]" and
"Blocked [s]" boxes.