Technical specifications
9.2 SCALANCE W7x8-2
SCALANCE W788-x / W748-1
72 Operating Instructions, 03/2022, A5E03678333-17
Technical specifications
Permitted ambient conditions
Ambient temperature
During operation
-20 to +60 °C
During storage
-40 °C to +70 °C
During transportation
-40 °C to +70 °C
Relative humidity
During operation
95% at 25 °C, no condensation
Operating altitude
During operation
2,000 m above sea level at max. 60 °C
ambient temperature
Contaminant concentration
According to IEC 60721
Degree of protection
IP code
RJ-45 variants
M12 variants
IP30
IP65
Dimensions and weight
Dimensions (W x H x D)
RJ-45 variants
M12 variants
200 x 158 x 79 mm
200 x 175.2 x 79 mm
Weight
1.7 kg
Installation options
Direct
Wall mounting
With additional holding plate
Mast mounting
Mounting on a DIN rail
Mounting on an S7-300 standard
rail
Mounting on an S7-1500 standard
rail
Mean time between failure
(MTBF)
At 40 °C ambient temperature
41 years

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE W788-x and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE W788-x Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE W788-x
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals