EasyManuals Logo

Siemens SIMATIC RF1040R User Manual

Siemens SIMATIC RF1040R
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
Programming
6.4 Status codes
SIMATIC RF1000
Operating Instructions, 11/2019, C79000-G8976-C432-06
49
The functions are constructed so that if execution fails, they are automatically repeated. This
compensates any communications problems that may occur, e.g. due to bad RF signal
quality as a result of external influences.
Table 6- 48 RS232-specific status codes
Value
Variable
Description
0x00
OK
No error
0x40
CMD_WORK
The job is currently being processed.
0x41 INVAILD_CMD_ERR Invalid function
Causes:
The function is not valid.
The parameters are invalid.
The response exceeds 255 bytes.
Missing configuration
0x42
ACCESS_DENIED_ERR
Missing authentication
0x81
TIMEOUT_ERR
The reader is currently in timeout.
0x82
FRAME_ERR
Invalid command from host.
0x83 AME_OVERFLOW_ERR The length of the response exceeds the maximum per-
missible length.
0x84
CHK_ERR
Invalid checksum in the host command.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC RF1040R and is the answer not in the manual?

Siemens SIMATIC RF1040R Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC RF1040R
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals