Appendix
A.1 Certificates & approvals
SIMATIC RF1000
64 Operating Instructions, 11/2019, C79000-G8976-C432-06
Marking
The EU conformity marking of the electrical equipment according to the ATEX, EMC, RoHS
directive is:
II
3 G Ex ec IIC T
4
Gc
II
3 D Ex tc IIIC T80 °C Dc
TÜV 19 ATEX 225698
Ta.:
-25 °C +55 °C
4.75 5.25 V DC, < 300 mA
Installation and operating conditions for hazardous areas
NOTICE
Notes on installation and use
Note the following conditions when installing, maintaining and operating the device in a
hazardous area:
The permissible ambient temperature range is -25 °C Ta 55 °C.
The RFID readers/writers must be protected against UV light.
EPL Gc: The RFID readers/writers can only be used in areas with degree of pollution 2
or better, as defined in IEC 60991-1.
The RFID readers/writers can only be commissioned in either II 3G or II 3D hazardous
areas. Hazardous areas with mixed atmospheres are not permitted.
During installation, the surface of the metal housing/frame must be smooth and clean.
The RFID readers/writers must be installed in a housing with wall thickness 2-7 mm.
The RFID readers/writers can only be installed in areas with a low risk of mechanical
danger.
The USB/RS232 cable must be secured with the supplied cable ties and adhesive
socket. You can only remove or connect the USB/RS232 cable when the power supply
is switched off or when the device is in an area without flammable gas or dust
concentrations.
The RFID readers/writers should only be cleaned with a damp cloth.
The RFID readers/writers cannot be installed close to charge-generating processes.
EPL Gc: The RFID readers/writers can only be installed in housings with ingress
protection of at least IP54 in accordance with EN 60079-0.
EPL Dc: The RFID readers/writers can only be installed in housings with ingress
protection of at least IP6X in accordance with EN 60079-0.
EPL Gc: It has to be guaranteed that the transient protection is set to a value that does
not exceed 140% of the measured peak voltage value at the USB/RS232 cable of the
housing.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC RF1040R and is the answer not in the manual?

Siemens SIMATIC RF1040R Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC RF1040R
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals