Parameter list 02.00
11-56 SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
P638
*
BDS
Source for selection of "Ramp-function generator setting 3”
Selection of binector to control switchover to "Ramp-function generator
setting 3".
With a log. "1" signal at the binector, ramp-function generator parameter set
3 (P311 - P314) is selected. This function has a higher priority than the
ramp-up integrator function.
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
P639
*
Source for the ramp-function generator setting values
Selection of the connectors that are connected as the ramp-function
generator setting values.
i001 Setting value for the ramp-function generator output in state log.
"1" of the binector selected via P640
i002 Setting value for the ramp-function generator output if the drive
is not in state "Operating" (B0104=0) and the binector selected
via P640 is in state log. "0"
[i002 only available with SW 1.6 and later]
0 = Connector K0000
1 = Connector K0001
etc.
All connector
numbers
1
Ind: 2
FS=167
Type: L2
P052 = 3
P051 = 40
≥off-line
P640
*
BDS
Source for selection of "Set ramp-function generator”
Selection of binector to control the "Set ramp-function generator"
function
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
P641
*
BDS
Source for selection of "Bypass ramp-function generator”
Selection of binector to control the "Bypass ramp-function generator"
function
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
P642
*
Source for variable positive limitation of main setpoint
Selection of connectors to be injected at the variable positive limitation of
the main setpoint.
The lowest value in each case of the connectors selected via the 4 indices
is applied as the limit.
Note: Negative values at the selected connectors result in a negative
maximum value at the output of the limitation.
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 4
FS=2
Type: L2
P052 = 3
P051 = 40
Offline
P643
*
Source for variable negative limitation of main setpoint
Selection of connectors to be injected at the variable negative limitation
of the main setpoint.
The lowest value in each case of the connectors selected via the 4 indices
is applied as the limit.
Note: Positive values at the selected connectors result in a positive
minimum value at the output of the limitation.
0 = connector K0000
...
8 = connector K0008
9 = value as set in parameter P642 ∗ (−1)
10 = connector K0010
etc.
All connector
numbers
1
Ind: 4
FS=9
Type: L2
P052 = 3
P051 = 40
Offline