Parameter list 02.00
11-96 SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U203
(2203)
*
S00
Source for input signal (A) and operating point (B) for FB 75
3
rd
limit-value monitor without filtering
i001: Input signal
i002: Operating point
Settings:
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 2
FS=
i001: 0
i002: 9188
Type: L2
P052 = 3
P051 = 40
Offline
U204
(2204)
S00
Settable operating point for limit-value monitor FB 75
Applied to connector K9188
-200.00 to 199.99
[%]
0.01%
Ind: None
FS=0.00
Type: I2
P052 = 3
P051 = 40
Offline
U205
(2205)
S00
Hysteresis for 3
rd
limit-value monitor without filtering FB 75
0.00 to 199.99
[%]
0.01%
Ind: None
FS=0.00
Type: O2
P052 = 3
P051 = 40
Offline
U206
(2206)
*
S00
Source for input signal (A) and operating point (B) for FB 76
4
th
limit-value monitor without filtering
i001: Input signal
i002: Operating point
Settings:
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 2
FS=
i001: 0
i002: 9189
Type: L2
P052 = 3
P051 = 40
Offline
U207
(2207)
S00
Settable operating point for limit-value monitor FB 76
Applied to connector K9189
-200.00 to 199.99
[%]
0.01%
Ind: None
FS=0.00
Type: I2
P052 = 3
P051 = 40
Offline
U208
(2208)
S00
Hysteresis for 4
th
limit-value monitor without filtering FB 76
0.00 to 199.99
[%]
0.01%
Ind: None
FS=0.00
Type: O2
P052 = 3
P051 = 40
Offline
U210
(2210)
*
S00
Source for input signal (A) and operating point (B) for FB 77
5
th
limit-value monitor without filtering
i001: Input signal
i002: Operating point
Settings:
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 2
FS=
i001: 0
i002: 9190
Type: L2
P052 = 3
P051 = 40
Offline
U211
(2211)
S00
Settable operating point for limit-value monitor FB 77
Applied to connector K9190
-200.00 to 199.99
[%]
0.01%
Ind: None
FS=0.00
Type: I2
P052 = 3
P051 = 40
Offline
U212
(2212)
S00
Hysteresis for 5
th
limit-value monitor without filtering FB 77
0.00 to 199.99
[%]
0.01%
Ind: None
FS=0.00
Type: O2
P052 = 3
P051 = 40
Offline
U213
(2213)
*
S00
Source for input signal (A) and operating point (B) for FB 78
6
th
limit-value monitor without filtering
i001: Input signal
i002: Operating point
Settings:
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 2
FS=
i001: 0
i002: 9191
Type: L2
P052 = 3
P051 = 40
Offline
U214
(2214)
S00
Settable operating point for limit-value monitor FB 78
Applied to connector K9191
-200.00 to 199.99
[%]
0.01%
Ind: None
FS=0.00
Type: I2
P052 = 3
P051 = 40
Offline
U215
(2215)
S00
Hysteresis for 6
th
limit-value monitor without filtering FB 78
0.00 to 199.99
[%]
0.01%
Ind: None
FS=0.00
Type: O2
P052 = 3
P051 = 40
Offline