02.00 Parameter list
SIEMENS AG 6RX1700-0AD76 11-97
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U216
(2216)
*
S00
Source for input signal (A) and operating point (B) for FB 79
7
th
limit-value monitor without filtering
i001: Input signal
i002: Operating point
Settings:
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 2
FS=
i001: 0
i002: 9192
Type: L2
P052 = 3
P051 = 40
Offline
U217
(2217)
S00
Settable operating point for limit-value monitor FB 79
Applied to connector K9192
-200.00 to 199.99
[%]
0.01%
Ind: None
FS=0.00
Type: I2
P052 = 3
P051 = 40
Offline
U218
(2218)
S00
Hysteresis for 7
th
limit-value monitor without filtering FB 79
0.00 to 199.99
[%]
0.01%
Ind: None
FS=0.00
Type: O2
P052 = 3
P051 = 40
Offline
11.56 Processing of connectors
Parameters apply only if optional S00 technology software is installed
Maximum selection FB 80, FB 174, FB 175, FB 176
The largest of the input values selected by 3 indices each of the parameter (x1, x2, x3) is applied to the output.
U220
(2220)
*
S00
Source for maximum selection
0 = Connector K0000
1 = Connector K0001
etc.
i001: x1 Maximum selection 1 (FB 80, Output = K9193)
i002: x2 Maximum selection 1
i003: x3 Maximum selection 1
SW 1.8 and later:
i004: x1 Maximum selection 2 (FB 174, Output = K9460)
i005: x2 Maximum selection 2
i006: x3 Maximum selection 2
i007: x1 Maximum selection 3 (FB 175, Output = K9461)
i008: x2 Maximum selection 3
i009: x3 Maximum selection 3
i010: x1 Maximum selection 4 (FB 176, Output = K9462)
i011: x2 Maximum selection 4
i012: x3 Maximum selection 4
All connector
numbers
1
Ind:
3
[up to SW
1.7]
12
[SW 1.8 and
later]
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
Minimum selection FB 81, FB 177, FB 178, FB 179
The smallest of the input values selected by 3 indices each of the parameter (x1, x2, x3) is applied to the output.
U221
(2221)
*
S00
Source for minimum selection
0 = Connector K0000
1 = Connector K0001
etc.
i001: x1 Minimum selection 1 (FB 81, Output = K9194)
i002: x2 Minimum selection 1
i003: x3 Minimum selection 1
SW 1.8 and later:
i004: x1 Minimum selection 2 (FB 177, Output = K9463)
i005: x2 Minimum selection 2
i006: x3 Minimum selection 2
i007: x1 Minimum selection 3 (FB 178, Output = K9464)
i008: x2 Minimum selection 3
i009: x3 Minimum selection 3
i010: x1 Minimum selection 4 (FB 179, Output = K9465)
i011: x2 Minimum selection 4
i012: x3 Minimum selection 4
All connector
numbers
1
Ind:
3
[up to SW
1.7]
12
[SW 1.8 and
later]
FS=0
Type: L2
P052 = 3
P051 = 40
off-line