Commissioning (hardware)
4.4 Fan
SIMOTION D4x5-2
110 Commissioning and Hardware Installation Manual, 02/2012
Table 4- 10 System variable fannecessary/fanexisting
System variable on the
device
States Description
fanbattery of the structfanbattery type (the system variables are of the enumfanbattery type)
MANDATORY Fan is required for operation of the device.
.fanexisting can be used to query whether
a fan is available.
Examples: D410-2, D4x5-2
OPTIONAL Fan can be used optionally. .fanexisting
can be used to query whether a fan is
available.
Examples: D425, D435
.fannecessary
NOT_MANDATORY Fan is not required for operation of the
device.
SINGLE Single fan is available.
Examples: D410-2
REDUNDANT Double fan is available.
Examples: D4x5-2
.fanexisting
1)
NOT_EXISTING No fan available.
Example: D425 and D435 without optional
fan
1)
Value for SIMOTION D4x5-2 is updated dynamically
References
Detailed information on setting up TaskStartInfo(#TSI) can be found in the
SIMOTION
SCOUT Basic Functions Function Manual.