Commissioning (hardware)
4.3 User memory concept
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 02/2012
93
Volatile SIMOTION data (RAM / current data RAM)
The volatile SIMOTION data is defined by the following properties:
The volatile SIMOTION data is located in the RAM memory of the SIMOTION device.
The download data of SIMOTION SCOUT is written to this memory.
This data is lost when the SIMOTION D4x5-2 is switched off.
The "volatile SIMOTION data" area contains the following data:
SIMOTION Kernel (D4x5-2 firmware)
Technology packages (TP)
User data (programs, configuration data, parameter settings)
520
0LFURPHPRU\FDUG
&RPSDFW)ODVKFDUG
0HPRU\FDUG
5$0
ORDGPHPRU\
&XUUHQW5$0
ZRUNLQJPHPRU\
1H[W
7DUJHWGHYLFH
&RQILJGDWD
GXULQJ581
6\VWHP
YDULDEOHV
&RS\
5$0WR
520
'RZQORDG
8SORDG
72UHVWDUW
RULPPHGLDWHO\
&RS\FXUUHQWGDWD
WR5$0
QRV\VWHPYDULDEOHV
&RPPLVVLRQLQJ
Figure 4-3 Configuration data and system variables in the volatile memory (memory concept,
principle)
Further information about memory management for SIMOTION is available in the
SIMOTION
SCOUT Basic Functions
Function Manual.

Table of Contents

Other manuals for Siemens SIMOTION D435-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D435-2 and is the answer not in the manual?

Siemens SIMOTION D435-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D435-2
CategoryControl Unit
LanguageEnglish

Related product manuals