EasyManua.ls Logo

Siemens SINAMICS V90 - Parameters

Siemens SINAMICS V90
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
10.2 Parameter list
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
373
Par. No.
Name
Min
Max
Factory
Setting
Unit
Data
type
Effective
Can be
changed
p29341
Warning 2 assigned for
digital output
1 6 2 - U16 IM T
Description:
Defines conditions for WARNING2.
1: Motor overload protection warning: 85% of overload threshold has been reached.
2: Holding brake power overload warning: threshold p29005 has been reached.
3: Fan warning: life time of fan expired (40000 hours), replacement of fan needed.
4: Encoder warning
5: Motor overtemperature warning: 85% of overtemperature threshold has been reached.
6: Capacitor service life warning: The capacitor has reached its expiry, so replace it.
p29350 Select sources for analog
output 1
0 12 0 - U16 IM T
Description:
Selects signal source for analog output 1.
0: Actual speed (reference p29060)
1: Actual torque (reference 3 × r0333)
2: Speed setpoint (reference p29060)
3: Torque setpoint (reference 3 × r0333)
4: DC bus voltage (reference 1000 V)
5: Pulse input frequency (reference 1k)
6: Pulse input frequency (reference 10k)
7: Pulse input frequency (reference 100k)
8: Pulse input frequency (reference 1000k)
9: Remaining number of pulses (reference 1k)
10: Remaining number of pulses (reference 10k)
11: Remaining number of pulses (reference 100k)
12: Remaining number of pulses (reference 1000k)
p29351 Select signal source for
analog 2
0 12 1 - U16 IM T
Description:
Selects signals for analog output 2.
0: Actual speed (reference p29060)
1: Actual torque (reference 3 × r0333)
2: Speed setpoint (reference p29060)
3: Torque setpoint (reference 3 × r0333)
4: DC bus voltage (reference 1000 V)
5: Pulse input frequency (reference 1k)
6: Pulse input frequency (reference 10k)
7: Pulse input frequency (reference 100k)
8: Pulse input frequency (reference 1000k)
9: Remaining number of pulses (reference 1k)
10: Remaining number of pulses (reference 10k)
11: Remaining number of pulses (reference 100k)
12: Remaining number of pulses (reference 1000k)