01.02 1 Alarms
© Siemens AG 2002 All Rights Reserved 6FC5598-3AA20-0BP2
SINUMERIK 802S/802C (DG) 1-99
No./Name Explanation Not allowed if Remedy
25. SINGLEBLOCK_
MAINBLOCK
Activate main
program single
block (BTSS
variable and VDI
signal: Activate
single block)
26. SINGLEBLOCK_PATH Activate travers-
ing single block
(BTSS variable
and VDI signal:
Activate single
block)
27. STARTPROG Start program
execution
(VDI signal: NC
Start)
1. program state active,
2. an alarm response is provided
which prevents start or forces de-
celeration.
3. reference-point approach not yet
carried out
⇒ -
⇒ Carry out alarm clear condi-
tion
⇒ Approach reference point
28. CHANNELSTARTPROG Start program
execution
(channel com-
munication, NC
block: Start)
1. program state active
2. an alarm response is provided
which prevents start or forces de-
celeration.
3. reference-point approach not yet
carried out,
4. inappropriate operating mode
selected (Automatic only)
⇒ Secure Start with WAITE
⇒ Carry out alarm clear condi-
tion
⇒ Approach reference point
⇒ Select program mode
29. RESUMEPROG Start continuation
of program
execution
(VDI signal: NC
Start)
1. program state active,
2. an alarm response is provided
which prevents start or forces de-
celeration.
3. reference-point approach not yet
carried out.
⇒ -
⇒ Carry out alarm clear condi-
tion
⇒ Approach reference point
30. RESUMEJOGREFDIGIT Start continuation
of selected
program mode -
Jog, Reference
Point or Digitalize
--.
(VDI signal: NC
Start)
1. Jog movement active
2. an alarm response is provided
which prevents start or forces de-
celeration.
⇒ -
⇒ Carry out alarm clear condi-
tion
31. STARTDIGITIZE Start program
execution in
Digitalize sub-
mode
(VDI signal: NC
Start)
1. Jog movement is active
2. an alarm response is provided
which prevents start or forces de-
celeration.
3. reference-point approach is not
yet carried out
⇒ -
⇒ Carry out alarm clear condi-
tion
⇒ Approach reference point
32. STOPALL Stop all axes.
(VDI signal: Stop
All or Reset key)
33. STOPPROG Carry out pro-
gram stop.
(NC block: M0)
34. STOPJOGREF Stop JOG
movement
(VDI signal: NC
Stop)
35. STOPDIGITIZE Stop digitaliza-
tion.
(VDI signal: NC
Stop)
36. STARTSIG Start selected
program mode
(VDI signal: NC
Start)
1. Process switch active (mode
change, Digitalize ON/OFF, Over-
store ON/OFF)
2. an alarm response is provided
which prevent start or forces de-
celeration.
3. a process is running (NC program,
block search, loading of machine
data)
⇒ -
⇒ Carry out alarm clear condi-
tion
⇒ -
37. STOPSIG Stop active
program mode
(VDI signal: NC
Stop)