Siemens SINUMERIK 804D sl - User Manual

Siemens SINUMERIK 804D sl
319 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Preface
Introduction
1
Safety information
2
Requirements for
commissioning
3
Example configuration
4
Power on and boot up
5
Connect PG/PC with the
PLC
6
PLC commissioning
7
Commissioning SINAMICS
drives
8
Commissioning
communication NCK<->Drive
9
NCK start-up
10
Optimize the drive.
11
Managing user data
12
Tips
13
Licensing
14
Fundamentals
15
Appendix
A
SINUMERIK SINAMICS
SINUMERIK 804D sl
SINAMICS S120
CNC Part 1 (NCK, PLC, drive)
Commissioning Manual
11/2006
6FC5397-2AP10-2BA0
Valid for
control
SINUMERIK 840D sl/840DE sl
drive
SINAMICS S120
Software
Version
NCU Software for 840D sl/840DE sl 1.4

Table of Contents

Questions and Answers

  • A
    Amanda GonzalezAug 9, 2025
    What to do if all four LEDs on the Siemens Controller PLC flash (DI disaster)?
    • A
      ashlee44Aug 9, 2025
      If all four LEDs on the Siemens Controller PLC are flashing, it indicates a system error. Here's what you should do: 1. Stop the PLC (set the "PLC" switch to position 2). 2. Perform a hardware reset. 3. Read the diagnostic buffer using STEP 7 to analyze the error in detail. 4. Relay the diagnostic buffer information to the Hotline / Development Service. 5. If requested after the hardware reset, perform a general reset. You can then read the diagnostic buffer with the PLC in the Stop state. Alternatively, resetting or reloading the PLC program might resolve the issue. Even if the system returns to normal, send the diagnostic buffer content to the Development Office.
  • R
    Rebecca LangAug 25, 2025
    How to troubleshoot no MPI connection to Siemens Controller PLC?
    • D
      Daniel GouldAug 25, 2025
      If there is no connection via MPI to the Siemens Controller PLC, the MPI cable might not be plugged in or could be defective. Also, the STEP 7 software might not be correctly configured for the MPI card. To test, create a link with the programmer in the STEP 7 editor using the "Direct_PLC" connection. A number of node addresses should appear. If they don't, the MPI cable is likely defective or not plugged in.

Siemens SINUMERIK 804D sl Specifications

General IconGeneral
Control System TypeCNC
Operating SystemSINUMERIK Operate
Axis ControlDigital
Power Supply24 V DC
TechnologyMilling, Turning
Communication InterfacesEthernet, USB
User InterfaceGraphical user interface
InterpolationLinear, circular