Overview of Alarms 11/2006
NCK alarms
2-16
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
1002 System error %1
Parameters: %1 = System error number
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the transferred error
number, provide information on the cause and location of the error.
Reaction: Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)
Program
Continuation:
Clear alarm with the Delete key or NC START.
1003 Alarm pointer for this self-clearing alarm %1 is zero
Parameters: %1 = Incorrect alarm number
Definitions: The address (zero pointer) used by the compile cycle manufacturer or by the operating system for self-
clearing alarms is not allowed in the system.
Reaction: Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)
Check setCCAlarm/setAlarm (...) call.
Program
Continuation:
Clear alarm with the Delete key or NC START.
1004 Alarm reaction to NCK alarm incorrectly configured
Parameters: %1 = Incorrect alarm number
Definitions: The alarm reaction configured by the operating system or the compile cycles manufacturer is
incorrect.
Reaction: NC not ready.
Channel not ready.
Interface signals are set.
Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)
Change alarm reaction
Program
Continuation:
Switch control OFF - ON.
1005 Operating system error %1 parameter %2 %3 %4
Parameters: %1 = Operating system error number
%2 = Operating system error parameter 1
%3 = Operating system error parameter 2
%4 = Operating system error parameter 3
Definitions: This alarm indicates that the operating system has detected a serious error.
Reaction: NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)
Program
Continuation:
Switch control OFF - ON.

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals