NCK alarms
11/2006 Overview of Alarms
2-17
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
1010 Channel %1 system error %2 action %3<ALNX>
Parameters: %1 = Channel number
%2 = System error number
%3 = Action number/action name
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the transferred error
number, provide information on the cause and location of the error.
Reaction: NC not ready.
Interpreter stop
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)
Program
Continuation:
Switch control OFF - ON.
1011 Channel %1 %3 %4 system error %2
Parameters: %1 = Channel number
%2 = System error number
%3 = Optional parameter: Block number, label
%4 = Optional parameter: Action number, ....
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the transferred error
number, provide information on the cause and location of the error.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)
Program
Continuation:
Clear alarm with the RESET key. Restart part program
1012 Channel %1 system error %2 %3 %4
Parameters: %1 = Channel number
%2 = System error number
%3 = Parameter1
%4 = Parameter2
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the transferred error
number, provide information on the cause and location of the error.
Reaction: Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)
Program
Continuation:
Clear alarm with the Delete key or NC START.