Overview of Alarms 11/2006
NCK alarms
2-18
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
1013 Channel %1 system error %2
Parameters: %1 = Channel number
%2 = System error number
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the transferred error
number, provide information on the cause and location of the error.
Reaction: Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)
Program
Continuation:
Clear alarm with the RESET key. Restart part program
1014 Channel %1 system error %2
Parameters: %1 = Channel number
%2 = System error number
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the transferred error
number, provide information on the cause and location of the error.
Reaction: Mode group not ready.
Local alarm reaction.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)
Program
Continuation:
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
1015 Channel %1 axis %2 system error %3
Parameters: %1 = Channel number
%2 = Axis number
%3 = System error number
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the transferred error
number, provide information on the cause and location of the error. Especially with parameter %3
(system error number) = 840001 = Problem with tool management, the identification for the axis is not
contained in parameter %2, but instead, further information for the diagnostics (= Status of the data
management/magazine no./location no./T no.)
Reaction: Local alarm reaction.
Channel not ready.
Interface signals are set.
Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)
Program
Continuation:
Clear alarm with the RESET key. Restart part program

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals