NCK alarms
11/2006 Overview of Alarms
2-19
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
1016 Channel %1 axis %2 system error %3
Parameters: %1 = Channel number
%2 = Axis number
%3 = System error number
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the transferred error
number, provide information on the cause and location of the error.
Reaction: Mode group not ready.
Local alarm reaction.
Channel not ready.
Interface signals are set.
Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)
Program
Continuation:
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
1017 Channel %1 axis %2 system error %3
Parameters: %1 = Channel number
%2 = Axis number
%3 = System error number
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the transferred error
number, provide information on the cause and location of the error.
Reaction: Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)
Program
Continuation:
Clear alarm with the Delete key or NC START.
1018 Floating point arithmetic error in channel %1 task %2 station %3 FPU
state %4
Parameters: %1 = Channel number
%2 = Task ID
%3 = Station priority
%4 = FPU status
Definitions: The floating point unit of the processor has found a computational error.
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Alarm reaction delay is canceled.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see alarm 1000)
Program
Continuation:
Clear alarm with the RESET key in all channels of this mode group. Restart part program.