HMI alarms
11/2006 Overview of Alarms
2-681
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
129903 Time determination is active.
Definitions: This indicates that time determination is enabled and that the user can press NC Start.
Reaction: Alarm display.
Remedy: Not necessary. As soon as all channels viewed for time determination are in Reset again, this
message will be cancelled automatically.
Program
Continuation:
Internal
129904 %1: Current NCK Version %2 is too low for time measurement. Version
500000 or higher will be required.
Parameters: %1 = Name of the NCU according to NETNAMES.INI
%2 = Current NCU version
Definitions: The version of the specified NCU is too old (< 500000).
Remedy: Upgrade or replace the relevant NCU for the required software version in order to use the time
determination.
129905 %1: Unable to determine the NCK version for time measurement.
Parameters: %1 = Name of the NCU according to NETNAMES.INI
Definitions: The version of the specified NCU could not be determined.
Remedy: Connect to the NCU and restart the PCU if required.
129906 %1: Unable to determine the number of channels.
Parameters: %1 = Name of the NCU according to NETNAMES.INI
Definitions: The number of channels of the specified NCU could not be determined.
Remedy: Connect to the NCU and restart the PCU if required.
129907 %1:The max. number of channels could not be determined.
Parameters: %1 = Name of the NCU according to NETNAMES.INI
Definitions: The maximum number of channels of the specified NCU could not be determined.
Remedy: Connect to the NCU and restart the PCU if required.
129908 %1: Unable to determine active channels.
Parameters: %1 = Name of the NCU according to NETNAMES.INI
Definitions: The active channels of the specified NCU could not be determined.
Remedy: Connect to the NCU and restart the PCU if required.
129909 %1: Unable to determine the name of channel %2.
Parameters: %1 = Name of the NCU according to NETNAMES.INI
%2 = Channel number
Definitions: The channel name of the specified NCU could not be determined.
Remedy: Connect to the NCU and restart the PCU if required.
129910 %1: Unable to determine general machine data.
Parameters: %1 = Name of the NCU according to NETNAMES.INI
Definitions: The general machine data of the specified NCU could not be determined.
Remedy: Connect to the NCU and restart the PCU if required.