EasyManuals Logo

Siemens SINUMERIK 810D Diagnostic Manual

Siemens SINUMERIK 810D
880 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #681 background imageLoading...
Page #681 background image
HMI alarms
11/2006 Overview of Alarms
2-681
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
129903 Time determination is active.
Definitions: This indicates that time determination is enabled and that the user can press NC Start.
Reaction: Alarm display.
Remedy: Not necessary. As soon as all channels viewed for time determination are in Reset again, this
message will be cancelled automatically.
Program
Continuation:
Internal
129904 %1: Current NCK Version %2 is too low for time measurement. Version
500000 or higher will be required.
Parameters: %1 = Name of the NCU according to NETNAMES.INI
%2 = Current NCU version
Definitions: The version of the specified NCU is too old (< 500000).
Remedy: Upgrade or replace the relevant NCU for the required software version in order to use the time
determination.
129905 %1: Unable to determine the NCK version for time measurement.
Parameters: %1 = Name of the NCU according to NETNAMES.INI
Definitions: The version of the specified NCU could not be determined.
Remedy: Connect to the NCU and restart the PCU if required.
129906 %1: Unable to determine the number of channels.
Parameters: %1 = Name of the NCU according to NETNAMES.INI
Definitions: The number of channels of the specified NCU could not be determined.
Remedy: Connect to the NCU and restart the PCU if required.
129907 %1:The max. number of channels could not be determined.
Parameters: %1 = Name of the NCU according to NETNAMES.INI
Definitions: The maximum number of channels of the specified NCU could not be determined.
Remedy: Connect to the NCU and restart the PCU if required.
129908 %1: Unable to determine active channels.
Parameters: %1 = Name of the NCU according to NETNAMES.INI
Definitions: The active channels of the specified NCU could not be determined.
Remedy: Connect to the NCU and restart the PCU if required.
129909 %1: Unable to determine the name of channel %2.
Parameters: %1 = Name of the NCU according to NETNAMES.INI
%2 = Channel number
Definitions: The channel name of the specified NCU could not be determined.
Remedy: Connect to the NCU and restart the PCU if required.
129910 %1: Unable to determine general machine data.
Parameters: %1 = Name of the NCU according to NETNAMES.INI
Definitions: The general machine data of the specified NCU could not be determined.
Remedy: Connect to the NCU and restart the PCU if required.

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals