EasyManua.ls Logo

Siemens SINUMERIK 810D - Page 816

Siemens SINUMERIK 810D
880 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Overview of Alarms 11/2006
PLC alarms
2-816
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
400173 Delete DB 73 in the PLC and restart
Definitions: The DB created by the basic program and the existing DB differ in size.
Reaction: Alarm display.
Remedy: Displayed DB must be deleted via STEP7. Possibly max. program size of the user program exceeded.
Program
Continuation:
Internal
400174 Delete DB 74 in the PLC and restart
Definitions: The DB created by the basic program and the existing DB differ in size.
Reaction: Alarm display.
Remedy: Displayed DB must be deleted via STEP7. Possibly max. program size of the user program exceeded.
Program
Continuation:
Internal
400176 Delete DB 76 in the PLC and restart
Definitions: The DB created by the basic program and the existing DB differ in size.
Reaction: Alarm display.
Remedy: Displayed DB must be deleted via STEP7. Possibly max. program size of the user program exceeded.
Program
Continuation:
Internal
400177 Delete DB 77 in the PLC and restart
Definitions: The DB created by the basic program and the existing DB differ in size.
Reaction: Alarm display.
Remedy: Displayed DB must be deleted via STEP7. Possibly max. program size of the user program exceeded.
Program
Continuation:
Internal
400201 PLC STOP due to DB loading in the RUN state: DB%Z
Parameters: %Z = Data block
Definitions: An existing DB was reloaded in the RUN state.
Reaction: Alarm display.
Remedy: Restart required.
Program
Continuation:
Switch control OFF - ON.
400202 Access error
Definitions: The data could not be accessed
Reaction: Alarm display.
Remedy: System error
Program
Continuation:
Switch control OFF - ON.
400250 NCK sign-of-life monitoring
Definitions: NCK has not contacted the PLC during cyclic operation. Timer of FB1 parameter NCCyclTimeout was
executed without retrigger.
Reaction: Alarm display.
Remedy: NCK restart
Program
Continuation:
Internal