11/2006 List of Action Numbers
3-833
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), Edition 11/2006
No. 8
No. 9
No. 10
No. 11
No. 12
Explanation Activate overstore (PI command).
Cause -
Remedy -
Explanation Activate overstore (PI command).
Cause -
Remedy -
Explanation Perform user interrupt "ASUB" (VDI signal: Digital-analog interface, ASUB interface).
Cause 1. The channel is active due to block search or loading machine data
2. The channel is stopped and the asynchronous subroutine "ASUP_START_MASK"
must be started and the current block cannot be reorganized.
3. Digitizing has been selected.
4. Reference point approach has not been performed yet.
5. The active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy − Wait until the block search or loading MD is completed, or abort program (Reset
key)
− Activate a block change until the NC block can be reorganized.
− Deactivate digitizing
− Perform reference point approach or ignore this state via the MD
"ASUP_START_MASK".
− Abort program
Explanation Perform "ASUB" user interrupt with rapid retraction (VDI signal: Digital-analog interface).
Cause See No. 10
Remedy -
Explanation Perform a user interrupt at the end of the block (VDI signal: ASUB interface, digital-ana-
log interface).
Cause See No. 10
Remedy -