EasyManua.ls Logo

Siemens Sinumerik 840 sl

Siemens Sinumerik 840 sl
2184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Examples
4.1 Axis monitoring
Basic logic functions: Axis monitoring, protection zones (A3)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
67
N83 $AC_WORKAREA_CS_LIMIT_PLUS[2,Z] = –600
N90 $AC_WORKAREA_CS_PLUS_ENABLE[2,A] = FALSE
N92 $AC_WORKAREA_CS_MINUS_ENABLE[2,A] = FALSE
Activate working area limitation group 2
In order to activate the working area limitation group 2, following instruction must exist in the
part program:
...
N100 WALCS2 ...
...

Table of Contents

Other manuals for Siemens Sinumerik 840 sl

Related product manuals