EasyManua.ls Logo

Siemens Sinumerik 840 sl

Siemens Sinumerik 840 sl
2184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Detailed description
2.4 Drive service display (for digital drives only)
Basic logic functions: Diagnostic tools (D1)
30 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Power section in i²t limitation HMI SW 6.3 and later
Limitation for protecting the power section against continuous overloading of the
SIMODRIVE 611 drives.
State 1: i
2
t-power section limitation has responded
State 0: i
2
t power section limitation has not responded
Display is valid for SIMODRIVE universal and SIMODRIVE digital.
Display corresponds to NST DB31, ... DBX95.7
("i
2
t-monitoring").
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2)
Heatsink temperature warning
Warning signal output by drive:
State 0: The heat sink temperature monitoring has not responded.
State 1: The heatsink temperature monitoring has responded.
Display corresponds to IS DB31, ... DBX94.1
("Heatsink temperature prewarning").
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2)
Motor temperature warning
Warning signal output by drive:
State 0: The motor temperature is below the warning threshold.
State 1: The motor temperature has exceeded the defined warning threshold.
The warning threshold corresponds to the machine data:
MD1602 $MD_MOTOR_TEMP_WARN_LIMIT (maximum motor temperature).
Display corresponds to NST DB31, ... DBX94.0 ("motor temperature prewarning").
References:
/FB1/ Function Manual Basic Functions; Various Interface Signals (A2)

Table of Contents