EasyManua.ls Logo

Siemens Sinumerik 840 sl

Siemens Sinumerik 840 sl
2184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Detailed description
2.3 Setpoint /actual-value system
Basic logic functions: Velocities, Setpoint/Actual Value Systems, Closed-Loop Control (G2)
54 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
'5,9(B(1&B5$7,2B180(5$>Q@
'5,9(B$;B5$7,2B180(5$>Q@
'5,9(B$;B5$7,2B'(120>Q@
,17B,1&5B3(5B00
/($'6&5(:B3,7&+
'5,9(B(1&B5$7,2B'(120>Q@
,QWHUQDOLQFUHPHQWVPP
(QFRGHULQFUHPHQWVPP
(1&B5(62/>Q@LQWHUQDOPXOWLSOLFDWLRQ
MD30300 $MA_IS_ROT_AX = 0
MD31000 $MA_ENC_IS_LINEAR[0] = 0
MD31040 $MA_ENC_IS_DIRECT[0] = 0
MD31020 $MA_ENC_RESOL[0] = 2048
MD31030 $MA_LEADSCREW_PITCH = 10
MD31080 $MA_DRIVE_ENC_RATIO_NUMERA[0] = 1
MD31070 $MA_DRIVE_ENC_RATIO_DENOM[0] = 1
MD31060 $MA_DRIVE_AX_RATIO_NUMERA[0] = 5
MD31050 $MA_DRIVE_AX_RATIO_DENOM[0] = 1
MD10200 $MN_INT_INCR_PER_MM = 10000

PPLQFUPP 
,QWHUQDOLQFUHPHQWVPP
(QFRGHULQFUHPHQWVPP
Result:
1 encoder increment corresponds to 0.004768 increments of the internal unit. In practice, the
available encoder resolution should not be resolved more accurately than the internal
computational resolution.

Table of Contents

Other manuals for Siemens Sinumerik 840 sl

Related product manuals