1 Alarms 10.04
1-662
ï›™ Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
410150 Area in M group decoder list is too large
Definitions: Number of M groups in PLC too large.
Reactions: - Alarm display.
Remedy: Reduce the number of groups
Program Continuation: Internal
410151 Magazine data for tool management missing in the PLC
Definitions: Magazine data are not available in the PLC. The start-up has not been completed,
although the option TOOLMAN has been activated.
Reactions: - Alarm display.
Remedy: Softkey Create PLC Data must be pressed during TOOLMAN start-up via MMC 103. Data
in data block DB4 must be set from DBB64 in MMC 100.
Program Continuation: Internal
411101 Impermissible Parameter Axis in FB11
Definitions: Axis parameter not within the permissible range.
Reactions: - Alarm display.
Remedy: Use permissible axis number.
Program Continuation: Internal
411501 Incorrect version of FB 15, > general reset, do not transmit FB 15 from project
Definitions: FB 15 does not match the basic program used.
Reactions: - Alarm display.
Remedy: General PLC reset. Use correct version of the basic program.
Program Continuation: Internal
411502 Incorrect basic PLC program version
Definitions: FB 15 does not match the basic program used.
Reactions: - Alarm display.
Remedy: Load the basic program that matches the NCK version.
Program Continuation: Internal
800000 Error: HiGraph group no. %A graph no. %N status %Z
Definitions: -
Reactions: - Alarm display.
Remedy: -
Program Continuation: Internal
810001 Error OB event, error analysis via STEP7 required
Definitions: Reduced PLC error message. STEP7 is required for exact analysis.
Reactions: - Alarm display.
Remedy: Diagnose with STEP7.
Program Continuation: Internal