03.04 1 Alarms
No. 12
Explanation Perform a user interrupt at the end of the block (VDI signal: ASUB interface, digital-analog
interface).
Not allowed if See 10
Remedy -
No. 13
Explanation Perform a rapid retraction (VDI signal: Digital-analog interface and ASUB interface, for
further actions see 10, 11, 12, 85, 86).
Not allowed if -
Remedy -
No. 14
Explanation Move tool - only with tool management (PI command).
Not allowed if -
Remedy -
No. 15
Explanation Perform deletion of distance-to-go or axis synchronization (VDI signal: deletion of dis-
tance-to-go or follow-up mode) (follow-up mode: e.g., on activation of axis motion).
Not allowed if 1. The nesting depth is too great.
2. The active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy > Abort the program.
> Abort the program.
No. 16
Explanation Abort repetition of subroutine (VDI signal: Delete number of subroutine repetitions).
Not allowed if 1. The nesting depth is too great.
2. The active block, after which deceleration takes place, cannot be reorganized
(occurs when deceleration takes place over several blocks).
Remedy > Abort the program.
> Abort the program.
No. 17
Explanation Abortion of subroutine processing (VDI signal: Program-level abort).
Not allowed if 1. The nesting depth is too great.
2. The active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy > Abort the program.
> Abort the program.
No. 18
Explanation Activate single block (VDI signal: Activate single block).
Not allowed if -
Remedy -
No. 19
Explanation Deactivate single block (VDI signal: Activate single block).
Not allowed if -
Remedy -