1 Alarms 03.04
1-666
ï›™ Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA), 10.04 Edition
No. 7
Explanation Change the mode to a manual mode
(VDI signal (mode group): JOG, TEACH_IN, REF).
Not allowed if 1. Nesting depth too great:
The current processing operation can be interrupted by various events (e.g., interrupt).
Depending on the event, ASUBs are activated.
These ASUBs can be interrupted in the same manner as the user program. Unlimited
nesting depth is not possible for ASUBs due to memory limitations. Example: An interrupt
interrupts the current program processing. Other interrupts with higher priorities interrupt
processing of the previously activated ASUBs.
2. The channel is active (program running, block search, loading machine data).
3. A channel has exited the mode group due to an interrupt.
4. Overstore or digitizing has been selected.
Remedy > Abort the program with the Reset key.
> Abort the program with the Reset key or stop the program (not with block search, load-
ing machine data).
> Abort the program with the Reset key or wait until the interrupt has finished.
> Deactivate overstore/digitizing.
No. 8
Explanation Activate overstore (PI command).
Not allowed if -
Remedy -
No. 9
Explanation Activate overstore (PI command).
Not allowed if -
Remedy -
No. 10
Explanation Perform user interrupt "ASUB" (VDI signal: Digital-analog interface, ASUB interface).
Not allowed if 1. The channel is active due to block search or loading machine data.
2. The channel is stopped, the "ASUP_START_MASK" ASUB must be started and the
current block cannot be reorganized.
3. Digitizing has been selected.
4. Homing has not yet been performed.
5. The active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy > Wait until block search or loading machine data has finished or abort program (Reset
key).
> Activate a block change until the NC block can be reorganized.
> Deselect digitizing.
>Perform homing or ignore this state via the "ASUP_START_MASK" MD.
> Abort the program.
No. 11
Explanation Perform "ASUB" user interrupt with rapid retraction (VDI signal: Digital-analog interface).
Not allowed if See 10
Remedy -

Other manuals for Siemens SINUMERIK 840D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D and is the answer not in the manual?

Siemens SINUMERIK 840D Specifications

General IconGeneral
SeriesSINUMERIK 840D
AxesUp to 31
ChannelsUp to 10
Operating SystemWindows-based
Power Supply24 V DC
Control Unit TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
InterpolationSpline
PLCIntegrated PLC
Data StorageCompactFlash, USB