62500 Channel %1 block %2: GWPS has been limited
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE446
Remedy: Check the limit value for GWPS and program a lower value in the NC program if necessary
62501 Channel %1 block %2: Speed has been limited
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE446
Remedy: Check speed and program a lower value in the NC program if necessary
62502 Channel %1 block %2: Dresser %4, GWPS has been limited
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE421
Remedy: Check limit value for GWPS and program a lower value in the NC program if necessary
62503 Channel %1 block %2: Dresser %4, speed has been limited
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE421
Remedy: Check speed and program a lower value in the NC program if necessary
62900 Channel %1 block %2: Incorrect source file
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program
Continuation:
Clear alarm with the RESET key. Restart part program
62901 Channel %1 block %2: Source file not available
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program
Continuation:
Clear alarm with the RESET key. Restart part program