NCK alarms
11/2006 Overview of Alarms
2-581
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
62313 Channel %1 block %2: The number of lines per page _PROTFORM[0] is
incorrect and is automatically adjusted.
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm triggered by following cycle: CYCLE106.
Remedy: Check _PROTFORM[0] in the program.
62314 Channel %1 block %2: Traverse path limitation via software end position,
collision detection activated, continue with NC START / cancel with
RESET.
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggered by the following cycle: CYCLE977
Remedy: Position the workpiece to be measured further away from the software end positions.
62315 Channel %1 block %2: Overwrite swivel data record TCARR = %4, yes ->
NC start, no -> reset
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggered by the following cycle: CYCLE996
Remedy:
62316 Channel %1 block %2: Overwrite TRAORIdata, yes -> NC start, no -> reset
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggered by the following cycle: CYCLE996
Remedy:
62317 Channel %1 Block %2: Tolerance of the linear vector %4 exceeded
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggered by the following cycle: CYCLE996
Remedy:
62318 Channel %1 Block %2: Tolerance of the rotary axis vector %4 exceeded
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggered by the following cycle: CYCLE996
Remedy: