Overview of Alarms 11/2006
NCK alarms
2-602
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
75260 RCTR: channel: %1, block: %2, tool parameters incorrect on block
editing
Parameters: %1 = Channel number
%2 = Block number
Definitions: On block editing incorrect tool parameters are detected:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Correct tool parameters.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
75265 RCTR: channel: %1, block: %2, unreachable position on block editing
Parameters: %1 = Channel number
%2 = Block number
Definitions: On block editing a non-approachable position is detected:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
75270 RCTR: channel %1, tool parameters incorrect on interpolation
Parameters: %1 = Channel number
Definitions: On interpolation incorrect tool parameters are detected:
Reaction: NC Start disable in this channel.
Alarm display.
NC Stop on alarm.
Remedy: Correct tool parameters.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
75275 RCTR: channel: %1, block: %2, unreachable position on interpolation
Parameters: %1 = Channel number
%2 = Block number
Definitions: On block interpolation a non-approachable position is detected:
Reaction: NC Start disable in this channel.
Alarm display.
NC Stop on alarm.
Remedy: Modify part program.
Program
Continuation:
Clear alarm with the RESET key. Restart part program