HMI alarms
11/2006 Overview of Alarms
2-621
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
101018 Read-in possible only in active PLC status !
Definitions: The current PLC status mode is not active, e.g. if the softkey "Change" was pressed.
Remedy: Switch the PLC status to active.
101019 Not possible to initialize the HMI internal PLC status!
Definitions: --
Remedy: --
101020 Not possible to backup the HMI internal PLC status!
Definitions: --
Remedy: --
101100 No access rights !
Definitions: The access level set is too low to open the selected window.
Remedy: Enter a higher password.
101110 Error on overall reset
Definitions: --
Remedy: --
101111 No axes configured !
Definitions: Due to an incomplete start-up, the image "Service axis" or "Axis machine data" cannot be selected.
Remedy: Complete start-up.
101112 No drives configured !
Definitions: Due to an incomplete start-up, the image "Service drive" cannot be selected.
Remedy: Complete start-up.
101113 No channels configured !
Definitions: Due to an incomplete start-up, the image "Channel machine data" cannot be selected.
Remedy: Complete start-up.
101114 No MSD configured !
Definitions: Due to an incomplete start-up or missing MSD drives, the image "MSD machine data" cannot be
selected.
Remedy: --
101115 No FDD configured !
Definitions: Due to an incomplete start-up or missing FDD/SLM drives, the image "FDD machine data" cannot be
selected.
Remedy: --
101130 Error return value undefined: %1 %2
Parameters: %1 = --
%2 = --
Definitions: A function was called up in the start-up area that then, for unknown reasons, could not be executed.
Remedy: When provided with the issued digits, the service may be able to help.