109001 No switchover: Switchover disable set in current PLC
Definitions: MMC would like to go offline from this NCU.
The MMC switchover is disabled in the MMC PLC online interface in DB19.
(MMCx_SHIFT_LOCK = TRUE, x = 1,2)
Remedy: --
109002 No switchover: Target PLC used, try again
Definitions: MMC would like to go online to this NCU.
MMC has called the target PLC and is awaiting acknowledgement.
MMC bekommt keine Quittung, da die MMC-Parameter-Schnittstelle in DB19 von einem anderen
MMC belegt ist.
Remedy: Repeat the operation at a later point in time, as the MMC parameter interface in DB19 is only
temporarily occupied.
109003 No switchover: Switchover disable set in target PLC
Definitions: MMC would like to go online to this NCU.
The MMC switchover is disabled in the MMC PLC online interface in DB19.
(MMCx_SHIFT_LOCK = TRUE, x = 1,2)
Remedy: The MMC switchover is disabled/enabled in the machine manufacutrer's
PLC program.
Reference to the machine manufacturer's documentation.
109004 No switchover: PLC occupied by higher-priority HMIs
Definitions: The MMC is attempting to switch to an NCU that is occupied by two higher-priority MMC's.
Remedy: Switch one of the two higher-priority MMC's to another NCU.
109005 No switchover: No HMI displaceable on target PLC
Definitions: MMC would like to go online to this NCU.
At this NCU, two MMC's are online on which uninterruptable processes are active (e.g.: data transfer
between MMC and NCU).
Remedy: Wait until at least one of the two MMC's can be displaced and repeat the switchover.
109006 No switchover: Selected channel invalid
Definitions: At this NCU, the MMC was switched to a channel that does not exist there.
Remedy: Set up the channel or adapt the parameterization of the NETNAMES.INI.
109007 Channel switchover running
Definitions: The channel switchover has been initiated.
A different MMC may have to be displaced.
Remedy: --
109008 Activation running
Definitions: The switchover from the passive operating mode to the active operating mode has been initiated.
Remedy: --
109009 Switchover: error in internal state
Definitions: --
Remedy: --