HMI alarms
11/2006 Overview of Alarms
2-661
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
112046 Main contour cannot be traced
Definitions: The pocket contour cannot be bypassed with the specified milling cutter.
Residual material will remain.
The program can be started.
This alarm is only a warning.
Reaction: Alarm display.
Remedy: By using a smaller milling cutter, the pocket contour could be bypassed.
Program
Continuation:
Internal
112052 No residual material available
Definitions: No residual material has been determined.
Reaction: Alarm display.
Remedy: Check parameters in the residual material cycle.
Program
Continuation:
Clear alarm with the Delete key or NC START.
112057 Programmed helix violates contour
Definitions: The starting point for helical insertion was so selected, that the helix violates the programmed contour.
The program can be started.
This alarm is only a warning.
Reaction: Alarm display.
Remedy: Select another starting point; use a smaller helix radius.
Program
Continuation:
Internal
112099 System error contour pocket %1
Definitions: While the contour pocket was being calculated, an error occurred. The contour pocket cannot be
calculated.
The program cannot be started.
Reaction: Alarm display.
Remedy: Please contact the hotline of Siemens AG, A&D MC and provide with the error message.
Program
Continuation:
Internal
112100 Error on renumbering.%nInitial state restored.
Definitions: The softkey "Renumber" was pressed in the program editor. This caused an error during serial
numbering that damaged the program in the memory, making it necessary to reload the initial program
into the memory.
The program was not renumbered.
Reaction: Alarm display.
Remedy: Make room in the memory, e.g. by deleting an old program. Select "Renumber" again.
Program
Continuation:
Internal