HMI alarms
11/2006 Overview of Alarms
2-665
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
112340 Approval not possible, as axes have not%nbeen referenced!
Definitions: In Safety Integrated a user acknowledgement can only be made after the reference point has been
approached.
Reaction: Alarm display.
Remedy: Approach reference point.
Program
Continuation:
Clear alarm with the Delete key or NC START.
112350 No swivel data created!
Definitions: There are no swivel data blocks.
Reaction: Alarm display.
Remedy: Set up swivel data blocks (see /FBSP/, ShopMill Description of Functions)
Program
Continuation:
Internal
112360 Step was not transferred into program chain%nas program run active.
Definitions: The program that you want to change is being executed in the operating mode "Machine auto". You
can only change programs that are not being executed in the operating mode "Machine auto".
Reaction: Alarm display.
Remedy: Stop the program run in the "Machine auto" operating mode.
Program
Continuation:
Internal
112400 Not stored in the Tool Management:%n%1 Program: %2
Definitions: The tool specified in the program does not exist.
Reaction: Alarm display.
Remedy: The tool must be created before the data is saved.
Program
Continuation:
Internal
112401 Tool could not be set up:%n%1
Definitions: When reading in the tool data, a tool could not be created.
Reaction: Alarm display.
Remedy: Check tool management.
Program
Continuation:
Internal
112402 Work offsets: error on writing
Definitions: Data could not be written to the NC.
Reaction: Alarm display.
Remedy: Should the alarm be displayed again after a new try, please contact the hotline of Siemens AG, A&D
MC.
Program
Continuation:
Clear alarm with the Delete key or NC START.