NCK alarms
11/2006 Overview of Alarms
2-535
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61300 Channel %1 Block %2: Probe defective
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61301 Channel %1 Block %2: Probe not switching
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The measuring distance was completely traversed but no switching signal was generated at the
measuring input.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy: -Check measuring input.
-Check measuring distance.
-Probe defective.
61302 Channel %1 Block %2: Probe - collision
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The measuring probe collided with an obstacle when being positioned.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy: ? Check spigot diameter (may be too small)
? Check measuring distance (may be to long)
61303 Channel %1 Block %2: Safety margin exceeded
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The measuring result differs greatly from the specified value.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy: -Check setpoint value.
-Increase parameter _TSA.
61304 Channel %1 Block %2: Allowance
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Continuation:
Clear alarm with the RESET key. Restart part program