Overview of Alarms 11/2006
NCK alarms
2-544
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61357 Channel %1 Block %2: No resources free
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
Not enough NC memory space available.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Delete the files.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61358 Channel %1 Block %2: Error during recording
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
Internal error
Remedy: Call the hotline!
61359 Channel %1 Block %2: - continue with RESET
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
Internal error
Remedy: Call the hotline!
61360 Channel %1 Block %2: Log job undefined - continue with RESET
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm triggered by following cycle: CYCLE106.
Cycle CYCLE106 was called by an incorrect parameter.
Remedy: Check cycle call for CYCLE106, specifically the call parameter.
61361 Channel %1 Block %2: Variable cannot be recorded
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE105.
The value specified in _PROTVAL[] cannot be logged.
Remedy: Check parameter _PROTVAL[].
61362 Channel %1 Block %2: Cycle118: No. of values too large
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE118.
4th parameter for CYCLE118 is larger than 10.
Remedy: Reduce the 4th parameter (PAR4) of CYCLE118.