NCK alarms
11/2006 Overview of Alarms
2-543
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61351 Channel %1 Block %2: Tool length or radius is 0
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE971.
For the active tool, the length or radius equal zero.
Remedy: Check length and radius of the active tool in the compensation data memory.
61352 Channel %1 Block %2: Path for logfile not permitted
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
The specified path for the log file is incorrect.
Remedy: Check parameter _PROTNAME[1].
61353 Channel %1 Block %2: Path for logfile not found
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
The specified directory does not exist or the specified path is incorrect.
Remedy: Check parameter _PROTNAME[1].
61354 Channel %1 Block %2: File for logfile not found
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
No name specified for the log file.
Remedy: Check parameter _PROTNAME[1].
61355 Channel %1 Block %2: Incorrect file type for logfile
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
The file extension for the log file is incorrect.
Remedy: Check parameter _PROTNAME[1].
61356 Channel %1 Block %2: File for logfile is being used
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE106.
The log file is already used by an NC program.
Remedy: Check parameter _PROTNAME[1].