61346 Channel %1 Block %2: Distance starting point/measuring point _SETV[0]
and _SETV[1] <=0
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE961.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Parameters _SETV[0] or _SETV[1] are empty or smaller than 0.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61347 Channel %1 Block %2: Angle 1st edge - 2nd edge equals 0
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE961.
Remedy: Parameter _INCA equals 0.
61348 Channel %1 Block %2: Angle rel. to reference edge equals 0
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61349 Channel %1 Block %2: Distance upper probe edge - measuring position =
0 for tool radius measurement
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE971.
Parameter _TP[x,9] distance between upper edge and lower edge of tool probe equals 0; relevant for
radius measurement.
Remedy: Check parameter _TP[x,9].
61350 Channel %1 block %2: feed, speed not programmed in _MFS for tool
measurement with rotating spindle
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE971.
Measuring feed and/or spindle speed of tool measurement with rotating spindle in GUD variable
_MFS[2] not specified.
Remedy: Check parameter _MFS[2].